Qusy F.Alsalhy; Jamal M.Ali; Khitam S.Shaker
Abstract
Membranes have gained an important place in chemical technology and are used in a wide range of applications. This investigation has studied the effect of operating conditions such ...
Read More ...
Membranes have gained an important place in chemical technology and are used in a wide range of applications. This investigation has studied the effect of operating conditions such as temperature, trans-membrane pressure and solute concentration on the separation performance of (PVC/ PS) hollow fiber membrane, which was prepared in the laboratory from 15% (PVC) and 2% (PS) using phase inversion method. An attempt was done to investigate the ability of PVC/PS hollow fiber membrane for ultrafiltration application. A (PVP) solute was used to measure (PVP) rejection of prepared membrane. The predicted flux was found to increase from (18.88 l/m2.hr) to 33.05 l/m2.hr) when the operation temperature was increased from (10Ž) to (30Ž).While it increased from (28.57 l/m2.hr) to (263.36 l/m2.hr) when the operation pressure was increased from (1bar) to (3bar). It was also found to decrease from(17.97 l/m2.hr) to (12.20 l/m2.hr) with increase solute concentration from (1000ppm) to (2500ppm). The rejection efficiency was equal to (99.93%) when using (2500ppm) solute. This is considered within UF range.